ECOGREEN
TECHNICAL PRODUCT BULLETIN #SW-74
USEPA, OEM REGULATIONS IMPLEMENTATION DIVISION
ORIGINAL LISTING DATE: NOVEMBER 17, 2021
"ECOGREEN"
I. NAME, BRAND, OR TRADEMARK |
---|
ECOGREEN Type of Product: Surface Washing Agent |
II. NAME, ADDRESS, AND TELEPHONE NUMBER OF MANUFACTURER/CONTACT |
---|
Rose Rock Products, LLC P.O. Box 721926 Oklahoma City, OK 73172 Phone: (405) 883-1095 E-mail: Ken.Murphy@RoseRockEnv.com Website: www.RoseRockEnv.com (Mr. Ken Murphy, CEO) |
III. NAME, ADDRESS, AND TELEPHONE NUMBER OF PRIMARY DISTRIBUTORS | |
---|---|
Rose Rock Products, LLC P.O. Box 721926 Oklahoma City, OK 73172 Phone: (405) 883-1095 E-mail: Ken.Murphy@RoseRockEnv.com Website: www.RoseRockEnv.com (Mr. Ken Murphy, CEO) |
EcoTec, LLC 3 Nancy Court, Suite 4 Wappingers Falls, NY 12590 Phone: (845) 897-0003 E-mail: WJordan@EcoTecLLC.com Website: www.EcoTecLLC.com (Mr. Wyatt Jordan) |
IV. SPECIAL HANDLING AND WORKER PRECAUTIONS FOR STORAGE AND FIELD APPLICATION |
---|
1. Flammability: Non-flammable. 2. Ventilation: Always keep exposure below permissible exposure limits. In general, dilution ventilation is a satisfactory health hazard control for this substance. However, if conditions of use create discomfort to the worker, a local exhaust system should be considered. 3. Skin and eye contact; protective clothing; treatment in case of contact: As prescribed in the OSHA Standard for Personal Protective Equipment (29 CFR 1910.132), employers must perform a Hazard Assessment for all workplaces to determine the need for, and selection of, proper protective equipment for each task performed. For skin and eye contact, use good normal hygiene and avoid contact with skin and eyes. For prolonged or repeated handling, use impervious gloves. Gloves should be tested to determine suitability for prolonged contact. Use of impervious apron and boots are recommended. Wear face shield, safety glasses, or chemical goggles are recommended for field application and product handling. If contact with eyes, flush with water for 15 minutes and see medical attention if irritation develops. For contact with skin, wash area with soap and water. May cause redness and drying of skin. Seek medical attention if irritation develops. In case of ingestion, seek medical attention. Not considered an inhalation risk. 4.a. Maximum storage temperature: 120°F. 4.b. Minimum storage temperature: Freeze temperature is 32°F. No deterioration in performance is expected as a result of freezing. Thaw product and mix thoroughly prior to use. 4.c. Optimum storage temperature range: 35°F to 120°F. 4.d. Temperatures of phase separations and chemical changes: Temperature fluctuations will not cause separation or deterioration of product. Product blend is stable and will not undergo phase separation of ingredients or stratification of contents over time. |
V. SHELF LIFE |
---|
Unlimited shelf life (unopened), product should be used within 12 months of opening. |
VI. RECOMMENDED APPLICATION PROCEDURE |
---|
1. Application Method: Dilute product with water prior to use. Apply diluted product via manual pressure applicator (i.e., hand pump), or other delivery equipment, to impacted surfaces. Allow product to soak prior to rinse/recovery if heavily saturated with oil. On hard surfaces, product may be applied and agitated with a brush or other physical means prior to recovery of effluent. Product may also by pre-mixed and used in a batch tank or through an eduction/metering system for flushing and recovery operations. Any common pressure washer, either hot or cold, will be effective for proper application at recommended dilutions of ECOGREEN. Proper containment contingencies should be deployed prior to application of ECOGREEN solution to stranded oils on impacted substrates to ensure adequate recovery of treated oils. 2. Concentration/Application Rate: ECOGREEN is a concentrated product and must be diluted prior to use. Concentrations vary based upon type of oil and degree of surface saturation. For Light Ends (i.e., gas condensate/gasoline) a 1% to 2% solution may be used to flush area to containment. Note: A higher concentration solution of 5% to 6% should be used if flammable vapor presents an explosion hazard. For Lighter Oils (i.e., Diesel Fuel, #2 Fuel Oil) a 3% solution may be used to flush impacted areas to containment. For Heavy Ends (i.e., Crude Oil, #6 Fuel Oil) a 6% solution of ECOGREEN should be applied and allowed to soak into containment/substrate for up to an hour to allow for release of oil. The surface should then be flushed to containment with a 1% to 3% solution of ECOGREEN. Product may be used as noted above through any pressure or steam equipment. The use of a “hot” unit is recommended when oils are at low temperature or have been weathered. 3. Conditions for Use: ECOGREEN may be diluted with hard, soft, brackish, salt, or most waters of sufficient quality for operations. Upon proper application as noted above, all treated fluids should be flushed and/or directed to proper containment and recovery. Affected shorelines and other surfaces should be isolated with containment booms and/or sorbent materials prior to treatment to avoid release of treated fluids to open waters. Diversion of swales and temporary catchment sumps may be used for vacuum recovery of treated effluents. All recovered fluids should be disposed of in accordance with all federal, state, and local regulations. |
VII.TOXICITY AND EFFECTIVENESS | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
a. Toxicity:
b. Effectiveness: NA |
VIII. MICROBIOLOGICAL ANALYSIS |
---|
NA |
IX. PHYSICAL PROPERTIES |
---|
1. Flash Point: >230°F 2. Pour Point: 32.0°F 3. Viscosity: 4.403 cSt @ 104°F 4. Specific Gravity: 1.015 @ 60°F 5. pH: 8.3 6. Surface Active Agents: CONFIDENTIAL 7. Solvents: CONFIDENTIAL 8. Additives: CONFIDENTIAL 9. Solubility in Water: Complete |
X. ANALYSIS FOR HEAVY METALS, CYANIDE, AND CHLORINATED HYDROCARBONS | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|