JEP-MARINE CLEAN
TECHNICAL PRODUCT BULLETIN #SW-57
USEPA, OEM REGULATIONS IMPLEMENTATION DIVISION
ORIGINAL LISTING DATE: MAY 11, 2011
"JEP-MARINE CLEAN"
(aka, ECOVOOM-MARINE)
I. NAME, BRAND, OR TRADEMARK |
---|
JEP-MARINE CLEAN Type of Product: Surface Washing Agent |
II. NAME, ADDRESS, AND TELEPHONE NUMBER OF MANUFACTURER/CONTACT |
---|
Nuance Solutions* 900 E. 103rd Street, Suite D Chicago, IL 60628 Phone: (800) 621-8553 Fax: (800) 621-1276 (Mr. Neil Houtsma) (*Nuance Solutions is the manufacturer for Jubilee Environmental Products, product owner) |
III. NAME, ADDRESS, AND TELEPHONE NUMBER OF PRIMARY DISTRIBUTORS | |
---|---|
Jubilee Environmental Products 406 S. Boulder, Suite 820 Tulsa, OK 74103 Phone: (918) 277-1113 Fax: (918) 296-3997 E-mail: jubilinc@aol.com Sales and Inquiries: Phone: (918) 277-1113 Fax: (918) 296-3997 E-mail: jubilinc@aol.com (Mr. Thomas J. Rhein, President) |
Restored Cleaner LLC 2475 Fairfield Ave. Bridgeport, CT 06605 Phone: (203) 335-9555 Fax: (203) 335-9550 E-mail: info@restoredcleaner.com Sales and Inquiries: Phone: (203) 335-9555 Fax: (203) 335-9550 E-mail: info@restoredcleaner.com (Mr. Colton Amster) |
IV. SPECIAL HANDLING AND WORKER PRECAUTIONS FOR STORAGE AND FIELD APPLICATION |
---|
1. Flammability: Non-flammable 2. Ventilation: Normal. 3. Skin and eye contact; protective clothing; treatment in case of contact: Respiratory protection not required under normal conditions. Protect against generated mists using protective clothing in order to minimize contact (i.e., boots, apron, face shield). Use safety glasses/goggles during handling and application to prevent eye contact. Wear rubber/PVC gloves to prevent skin contact. 4.a. Maximum storage temperature: 90°F 4.b. Minimum storage temperature: 40°F 4.c. Optimum storage temperature range: 40 – 90°F; product freezes at 32°F 4.d. Temperatures of phase separations and chemical changes: 120°F |
V. SHELF LIFE |
---|
In unopened containers, shelf life is minimum 2 years. |
VI. RECOMMENDED APPLICATION PROCEDURE |
---|
1. Application Method: Product may be diluted with fresh or salt water, and may be applied to any type of surfaces that have been coated with oil or other petroleum-based substances resulting from a spill (e.g., beaches, rocks). Manual pump sprayers should be used to presoak the contaminated areas, and pressure washers should be used to agitate the contaminated areas after a presoak has been applied. 2. Concentration/Application Rate: Shoreline Cleaning – presoak the surface needing to be cleaned, using a manual pump sprayer, with a dilution rate of one (1) part to three (3) parts water for approximately 10 to 15 minutes, without letting the product dry or evaporate. After the contaminated areas have been presoaking for the allotted time, run a dilution rate of one (1) part product to fifteen (15) parts water, through a pressure washer directly onto the contaminant. 3. Conditions for Use: Option temperature range for use is 45 to 212°F. When the contaminants have been released, they can be removed using sorbent pads, suction booms or skimmers, and hauled away and disposed of according to local, state, and federal law. It is recommended that for older or crustier contaminants higher pressure and stronger dilutions be used. |
VII.TOXICITY AND EFFECTIVENESS | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
a. Toxicity:
b. Effectiveness: NA |
VIII. MICROBIOLOGICAL ANALYSIS |
---|
NA |
IX. PHYSICAL PROPERTIES |
---|
1. Flash Point: >100°C 2. Pour Point: -14°C 3. Viscosity: 1.1 cSt 4. Specific Gravity: 1.041 5. pH: 11.2 6. Surface Active Agents: CONFIDENTIAL 7. Solvents: Water 8. Additives: CONFIDENTIAL 9. Solubility: Miscible with water |
X. ANALYSIS FOR HEAVY METALS, CYANIDE, AND CHLORINATED HYDROCARBONS | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|