X4JH2000
TECHNICAL PRODUCT BULLETIN #SW-70
USEPA, OEM REGULATIONS IMPLEMENTATION DIVISION
LISTING DATE: MARCH 05, 2019
"X4JH2000"
I. NAME, BRAND, OR TRADEMARK |
---|
X4JH2000 Type of Product: Surface Washing Agent |
II. NAME, ADDRESS, AND TELEPHONE NUMBER OF MANUFACTURER/CONTACT |
---|
X4 Environmental Inc. 14702 Jersey Shore Drive Houston, TX 77047 Phone: (281) 846-6003 E-mail: benlux.tam@x4environmental.com (TszFung Benlux Tam) |
III. NAME, ADDRESS, AND TELEPHONE NUMBER OF PRIMARY DISTRIBUTORS |
---|
X4 Environmental Inc. 14702 Jersey Shore Drive Houston, TX 77047 Phone: (281) 846-6003 E-mail: benlux.tam@x4environmental.com (TszFung Benlux Tam) |
IV. SPECIAL HANDLING AND WORKER PRECAUTIONS FOR STORAGE AND FIELD APPLICATION |
---|
1. Flammability: Non-flammable 2. Ventilation: Recommend using a respirator in confined areas. 3. Skin and eye contact; protective covering; treatment in case of contact: Wear rubber gloves and eye protection. In case of eye contact, wash eyes thoroughly for 15 minutes including upper and lower lids; and seek medical attention. In case of skin contact, irritation is possible; wash with soap and water for 15 minutes. If irritation persists, seek medical attention. 4.a. Maximum storage temperature: 95°F 4.b. Minimum storage temperature: 32ºF 4.c. Optimum storage temperature range: 75°F 4.d. Temperatures of phase separations and chemical changes: No phase changes have been observed |
V. SHELF LIFE |
---|
One year in a sealed container; and six months for an opened container. |
VI. RECOMMENDED APPLICATION PROCEDURE |
---|
1. Application Method: X4JH2000 is applied by spraying apparatus or mixing on or into media using excavator and 2-inch discharge hose, fire nozzle, or water pump; and water trucks. 2. Concentration/Application Rate: X4JH2000 is a water-based chemical. Use a ratio of 1 to 1.5 U.S. gallons of X4JH2000 to 10 parts water (i.e., tap, salt or fresh water) per cubic yard of contaminated media. 3. Conditions for Use: Ambient temperature should be above 50ºF. Water salinity and age of hydrocarbon pollutants are not a condition of use. Prior to application, use oil spill absorbent, boom and/or pad to prevent X4JH2000 from run off into ditches, creeks, and waterways. Place collected booms, pads, and absorbents in black 55-gallon poly-bags, use duct tape to seal, and then place bags in hazardous waste container for disposal. Collected containment materials should be disposed of according to local, state, and federal regulations. |
VII. TOXICITY AND EFFECTIVENESS | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
a. Toxicity:
b. Effectiveness NA |
VIII. MICROBIOLOGICAL ANALYSIS |
---|
NA |
IX. PHYSICAL PROPERTIES |
---|
1. Flash Point (ASTM D-56): >220ºF 2. Pour Point (ASTM D-57): +28ºF 3. Viscosity (ASTM D-445): 4.99cSt at 40ºC 4. Specific Gravity (ASTM D-1298): 1.06 at 60ºF 5. pH (ASTM D-1293): 4.69 6. Surface Active Agents: HS Code 340211 anionic organic surface-active agents 7. Solvents: Not applicable 8. Additives: Not applicable 9. Solubility in Water: Not applicable |
X. ANALYSIS FOR HEAVY METALS, CYANIDE, AND CHLORINATED HYDROCARBONS | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|