Search Frequent Questions
Filter By:
-
Risk Management Program (RMP)
Total results: 284
- Applicability/General Duty Clause Total results: 69
- Emergency Response Total results: 6
- Five-Year Accident History Total results: 16
- Offsite Consequence Analysis (OCA) Total results: 57
- Other Risk Management Programs Total results: 34
- Plan Preparation and Submission Total results: 49
- Prevention Program Total results: 30
- Program Levels Total results: 16
- RMP*Comp Total results: 7
- Agriculture Total results: 9
- Air Emissions Inventories Total results: 33
- Asbestos Total results: 141
- Butte Area/Silver Bow Creek Total results: 11
- Compliance Total results: 18
- Coronavirus (COVID-19) Total results: 23
- East Palestine, Ohio Train Derailment Total results: 149
- Emergency Planning and Community Right-to-Know Total results: 267
- Enforcement Total results: 21
- Fuel Program Total results: 648
- Great Lakes Funding Total results: 53
- Indoor Air Quality Total results: 2
- MOVES Total results: 57
- Norwood Landfill Site Total results: 30
- Oil Regulations Total results: 96
- Permitting Under the Clean Air Act Total results: 13
- Public Engagement Total results: 1
- Radiation Total results: 1
- Red Hill Bulk Fuel Storage Facility in Hawai'i Total results: 39
- Smurfit-Stone Mill Total results: 12
- Southeast Minnesota Groundwater Total results: 11
Displaying 46 - 60 of 284 results
-
Calculating thresholds for toxic substances with concentration qualifiers
Several toxic substances are listed as regulated substances under 40 CFR §68.130 with concentration qualifiers (e.g., "conc 37% or greater"). What does this concentration mean? When determining whether a threshold amount of these substances exists in a process, should I consider the weight of the entire solution, or simply the…
- Last published:
-
Hydrochloric acid and hydrogen chloride listed separately
Why are hydrochloric acid and hydrogen chloride listed separately in the list of regulated substances at 40 CFR §68.130? The aqueous form (hydrochloric acid) and the anhydrous form of this chemical (hydrogen chloride) have been assigned different thresholds.
- Last published:
-
How did the January 6, 1998, final rule affect the definition of stationary source?
How did the January 6, 1998, final rule ( 63 FR 640) affect the definition of stationary source, as it relates to the transportation exemption? The January 6, 1998 final rule amended the regulatory definition of stationary source by removing previous references to "active shipping papers" and "temporary storage" and…
- Last published:
-
Must separate amounts of regulated substances be aggregated for threshold determinations?
Drums containing regulated substances (listed in 40 CFR §68.130) are stored in several separate locations at a stationary source and there is no possibility that an accidental release in any of the individual storage areas would impact any of the other storage areas. Must the overall amount of the regulated…
- Last published:
-
Who Must Develop an Emergency Response Program?
The risk management program regulations require the owner or operator of a covered stationary source to develop and implement an emergency response program as described in 40 CFR §68.95, which must include an emergency response plan, emergency response equipment procedures, employee training, and procedures to ensure the program is up-to-date…
- Last published:
-
RMP*eSubmit preparer access
How does a new Preparer get access to a Risk Management Plan (RMP) via RMP*eSubmit? First, the person must register with CDX. To register with CDX, go to https://cdx.epa.gov/ and complete the registration process for a Risk Management Plan “Preparer”. Once set up as a “Preparer”, the Certifying Official needs…
- Last published:
-
How does EPA verify accuracy and completeness of RMPs?
What does EPA plan to do to verify the accuracy and completeness of submitted Risk Management Plans (RMPs)? All RMPs received by EPA go through an electronic verification process that checks the submission for its completeness. This completeness check determines whether information has been provided for all of the required…
- Last published:
-
Five-year Anniversary Due Date and Time
Pursuant to the risk management program regulations in 40 CFR §68.190, the owner or operator of a stationary source shall revise and update the RMP at least once every five years from the date of initial submission. At what time on the 5-year anniversary date is the RMP due? The…
- Last published:
-
Required Contractor Contact Information
A facility that uses a contractor to prepare its RMP must include in the registration section the name, mailing address, and telephone number of the contractor who prepared the RMP (40 CFR §68.160(b)(14)). When a contractor only prepares a portion of an RMP on behalf of a facility, does the…
- Last published:
-
Are on-site areas with unrestricted access considered public receptors?
A process covered under 40 CFR Part 68 is eligible for Program 1 requirements if it meets all of the criteria listed at 40 CFR §68.10(b). One of those criteria is that the distance to a toxic or flammable endpoint for a worst-case release assessment is less than the distance…
- Last published:
-
Are areas occupied solely by employees considered public receptors?
When analyzing off-site consequences for the purpose of a worst-case or alternative release scenario under the risk management program regulations (40 CFR Part 68), are areas occupied solely by employees at the source considered to be public receptors? No. Such areas at the stationary source are not to be included…
- Last published:
-
Do Program Level 1 processes need to do five-year accident histories?
What is the relationship between the accident history criteria for Program 1 and the five-year accident history? If my process is eligible for Program 1, do I still need to do a five-year accident history? The five-year accident history is an information collection requirement that is designed to provide data…
- Last published:
-
Is the RMP submission date the postmark date or EPA's receipt?
Initial RMPs must be "submitted" by a certain date, and RMPs must be updated at least every five years from the date of its submission. What constitutes "submission" for purposes of meeting and determining these deadlines - postmarking the RMP or EPA's receipt of the RMP by the due date…
- Last published:
-
Would change in population data require an RMP update?
As part of the hazard assessment under 40 CFR Part 68, Subpart B, a source is required to estimate in its risk management plan (RMP) the population within a circle that has its center at the process and its radius equal to the distance to the endpoint concentration (40 CFR…
- Last published:
-
Are barracks and family housing units on military bases considered public receptors?
Barracks are not considered public receptors, family housing units are. Public receptors include any "offsite residences ... inhabited or occupied by the public at any time without restriction by the stationary source where members of the public could be exposed to toxic concentrations, radiant heat, or overpressure, as a result…