Search Frequent Questions
Filter By:
-
Risk Management Program (RMP)
Total results: 284
- Applicability/General Duty Clause Total results: 69
- Emergency Response Total results: 6
- Five-Year Accident History Total results: 16
- Offsite Consequence Analysis (OCA) Total results: 57
- Other Risk Management Programs Total results: 34
- Plan Preparation and Submission Total results: 49
- Prevention Program Total results: 30
- Program Levels Total results: 16
- RMP*Comp Total results: 7
- Agriculture Total results: 9
- Air Emissions Inventories Total results: 33
- Asbestos Total results: 141
- Butte Area/Silver Bow Creek Total results: 11
- Compliance Total results: 18
- Coronavirus (COVID-19) Total results: 23
- East Palestine, Ohio Train Derailment Total results: 149
- Emergency Planning and Community Right-to-Know Total results: 267
- Enforcement Total results: 21
- Fuel Program Total results: 648
- Great Lakes Funding Total results: 53
- Indoor Air Quality Total results: 2
- MOVES Total results: 57
- Norwood Landfill Site Total results: 30
- Oil Regulations Total results: 96
- Permitting Under the Clean Air Act Total results: 13
- Public Engagement Total results: 1
- Radiation Total results: 1
- Red Hill Bulk Fuel Storage Facility in Hawai'i Total results: 39
- Smurfit-Stone Mill Total results: 12
- Southeast Minnesota Groundwater Total results: 11
Displaying 106 - 120 of 284 results
-
Which chemicals are covered by the general duty provisions?
For CAA section 112(r)(1), General Duty, what are the chemicals that are covered? There is no specific list of substances which subject a stationary source owner or operator to the general duty provisions. The general duty provisions apply to owners and operators of all stationary sources which have any "extremely…
- Last published:
-
Do the risk management program regulations cover the loading and unloading of transportation containers?
Would the risk management program regulations cover the loading and unloading of transportation containers? The definition of stationary source includes transportation containers used for storage not incident to transportation and transportation containers connected to equipment at a stationary source for loading or unloading (40 CFR Section 68.3). In a January…
- Last published:
-
Are methane processes at landfills subject to RMP?
Some landfills collect methane gas and either vent, flare, or store it for subsequent fuel use. Are methane processes at landfills subject to the requirements of the EPA Risk Management Program? In general, methane processes at landfills will not be covered under the Risk Management Program. Methane that is collected…
- Last published:
-
Are bulk storage terminals exempt from filing a Risk Management Plan?
There is no general exemption for bulk storage terminals. However, the threshold exemption for "regulated substances in naturally occurring hydrocarbon mixtures prior to entry into a natural gas processing plant or a petroleum refining processing unit" would exempt certain storage terminals, such as crude oil storage terminals where the regulated…
- Last published:
-
Will the general duty clause be delegated?
The general duty clause (CAA section 112(r)(1)) is not included in Part 68 and, therefore, will not be delegated to states that have taken implementation of the RMP program. States, however, may adopt their own general duty clause under state law.
- Last published:
-
RMP Covered Facilities
Who is covered by the RMP rule under CAA §112(r)(7)? Section 112(r) of the CAA contains several provisions. The two most relevant to the regulated community at this time are Sections 112(r)(1) and 112(r)(7). Owners and operators of stationary sources at which regulated or any other extremely hazardous substances are…
- Last published:
-
Vulnerable Zone Determination
Vulnerable zones are areas that could be affected by a release from a chemical accident at a facility subject to the risk management program requirements in 40 CFR Part 68. How can one determine if they live or work within a vulnerable zone? The Vulnerable Zone Indicator System (VZIS) allows…
- Last published:
-
Can positive buoyancy models be used?
Yes, provided there is a basis for use and the owner or operator explains the rationale for use of positive buoyancy models.
- Last published:
-
Are valves in piping considered administrative controls?
No, administrative controls are written procedures that limit the quantity stored or flowing through the pipes. Valves are considered active mitigation systems.
- Last published:
-
Who is responsible for preparing and submitting an RMP for leased propane tanks?
If an owner of a stationary source leases propane tanks from a gas supplier, who is responsible for preparing and submitting the risk management plan (RMP) addressing the propane tanks? The owner of the stationary source is responsible for preparing and submitting the RMP. The risk management program regulations apply…
- Last published:
-
Acid aerosol reducing additive as passive mitigation
A refinery uses a special proprietary additive to their hydrofluoric acid (HF) alkylation process. This HF additive has shown in tests to significantly reduce aerosol forms of HF during accidental releases, and therefore reduce the distance traveled by HF releases. The additive is present at all times during the alkylation…
- Last published:
-
Is the off-site death of livestock considered environmental damage?
Under the hazard assessment requirements of 40 CFR Part 68, Subpart B, an owner or operator must document a five-year accident history including all accidental releases from covered processes that resulted in deaths, injuries, or significant property damage on site, or known offsite deaths, injuries, evacuations, sheltering in place, property…
- Last published:
-
State air permitting agency assigning EPA implementation and enforcement
Can a state air permitting agency unilaterally assign to EPA the implementation and enforcement of the requirements of 40 CFR Part 68.215(e)? No, such reassignment of responsibilities can only be achieved by the state entering into a written agreement with the Administrator under which EPA will implement and enforce the…
- Last published:
-
Worst-case release scenarios for toxics and flammables in same process
The owner or operator of a stationary source subject to the risk management program regulations must analyze the worst-case release scenario involving a Program 2 or 3 process containing a regulated flammable substance and the worst-case release scenario involving a Program 2 or 3 process containing a regulated toxic substance…
- Last published:
-
Withdrawal of an erroneous RMP submission
What should a facility do if it submitted a risk management plan (RMP) but later discovers that it was never subject to the risk management program requirements? If a facility discovers that it submitted an RMP in error and was never subject to the risk management program regulations, it should…
- Last published: